Register Please register or log in.
may be you forgot your password?

***IMMEDIATE ...

ONLY THE BEST Journeyman Electricians NEED APPLY!
Mister Sparky is looking for an exceptional and experienced residential service Journeyman. We are the best of the best!

(We are 99% residential service/existing homes, little commercial). Looking for only ‘A’ Players!

Our chosen candidate looks like–

• Has strong existing residential service experience
• Be on time in clean and pressed uniform, shoes shined, shaving prior to meetings – clean cut a must.
• Great customer service and customer communication skills a MUST.
• An accurate residential trouble shooter, neat, clean up-to-code work.
• A CAN-DO infectiously positive/optimistic attitude, great team member, takes ownership, plays at the top of their game.
• Able to estimate, educate, sell and up-sell quality products and superb ongoing services customers need to maintain and advance their greatest asset – their home.
• There is no income ceiling – the answer’s in the mirror!
• Willing to serve the customer and team mates first
• Has a strong work ethic, drive, initiative, tenacity, ambition, never satisfied with status quo – loves the challenge!
• Self taught, coachable, spirit of excellence, takes instruction and responsibility for personal growth & bettering themselves.
• Not a whiner but a problem solver, HATES mediocrity
• Able to lift 75lbs+ and get in/out of box trucks
• Able to physically get into attics and under houses
• Able to overcome objections professionally by being able to explain electrical problems and solutions in layman’s terms, give intelligent and forward thinking options and recommendations.
• Able to perform repairs to Mister Sparky quality control standards.
• Making sure job is totally cleaned up - for that 100% customer satisfaction before leaving EVERY job.
• Keeps van well stocked and organized to Mister Sparky standards
• Able to work long hours, average 40-50 a week, some weekends and be on call rotating basis-willing to work staggered week
• Must have current Texas electrical and drivers license, clean driving record, able to pass background/drug test, (PLEASE NOTE: do not apply if any of these are an issue).
• Be a fun, energetic, dependable, ‘whatever’ it takes team member!

Mister Sparky Company Culture:
This position must be filled be an upbeat top class Journeyman that not only performs his craft with a high degree of excellence but will also join and grasp strongly the complete vision of taking this company (and him/herself) to the next level of the company’s market and (therefore) income potential.
 
The modern and forward thinking Mister Sparky company culture is one where the Tech is given powerful tools to build continued relationships with the customer creating an unforgettable trust and complete, highly valued, on going service experience.
 
The exceptional Tech that embraces and potentializes all the “tools” available can achieve a growing,  exceptional reward.
 
Every customer will feel grateful you and Mister Sparky came and conquered and are there for both their immediate emergencies and their home’s electrical advancement and safety!

Benefits include –

• Base plus pay for performance compensation system
• Vacation, personal days, full benefits and insurance
• 401k
• Room for growth
* Working with great people, growth potential-(answers in the mirror!)-great culture, having fun while being paid well!

Used Conventional and Pad ...

ONLINE AUCTION- Ends 3/30/17. To see full details for this item please go to www.govdeals.com and enter QAL #1925-395 in the Quick Asset Lookup QAL box located on the home page. 

Used Conventional and Pad Mount Transformers, KVA's range from 1.5 to 750. These Transformers, Breaker and Regulators are not in working conditions. Oil has been drained out of most transformers, but can be re-built. Oil has been drained out of some of the regulators, not in working condition but can be re-built. Some regulators that contain oil can be put back into service. Please Note, Pad Mount Transformer, 300 KVA with serial #21900-0789 can NOT be re-built, it has been hit. The City of Martinsville will load these transformers, breakers and regulators onto your vehicle with our tow motor and line truck. The successful bidder will sign a release form stating they release the City of Martinsville from liability and responsibility for any damages to their vehicle or injuries to any persons incurred during the loading of these transformers, breakers and regulators. The successful vendor will be required to provide a large enough vehicle for transporting these transformers, breaker and regulators in one pick-up. More information and list of items available on auction page. 


CT Analyzer

Product Features
1.  5.7inch LCD screen display.
2.  Full functions, satisfy all kinds of CT(protection CT, measuring CT, TP) test requirements, such as excitation characteristic test, turn ratio, polarity, secondary winding resistance, secondary burden, ratio error, angular difference and etc. Also it can be used to test excitation characteristic, turn ratio, polarity, secondary winding resistance,ratio error, angular difference and etc all kinds of PT.
3.  More efficient to test CT, no need to use standard CT, primary current injection device, load case, voltage   regulation control and high current lead to verify the CT.
4.  Meets IEC60044-1, IEC60044-6 standards of all kinds of CT/PT.
5.  Accurately measure ratio error and angular error. Max. Ratio error ±0.05% is permitted. Max. Angular error ±2min if permitted. It can measure 0.2S class CT and turns ratio range is 1-35000.
6.  Auto test CT/PT parameters on knee point voltage/current, 5% and 10% deviation curve measurement,  Accuracy limit factor (ALF), safety factor (FS), second time constants (Ts), residual magnetism factor(Kr),  saturated and unsaturated inductance.
7.  Using variable frequency method to test VA curves and 10% error curve of CT/TP. Max. Output is 180V and 5A rms(15A peak value), but it can make CT test when keen point is up to 60kV.
8.  Easy to use. To test CT DC resistance, excitation and polarity only by one button. All CT tests adopt same     one connect method except load test.
9.  Storage 1000 groups data, data can be saved even power down. Equipped with micro printer to print test result after testing completed.
10. Test results can be download by USB disk.
11.  Small size, weight is no more than 10kg, suitable for on-site use.



 

Click >>> Subscribe to Our Store Newsletter <<<
for New Product info & Specials

website contact
Terms of Use